Old LPG cylinder refurbishment process
Main technical requirements of incinerators
1) Equipments: 1 set, including incinerator body, burner, fuel supply system (with fuel pressure reducer and related valves, pipes, filters, pressure meters, safety venting system), flue gas treatment equipment, flue gas chimney, flue gas, etc.
2) Furnace temperature: <650, according to the requirements of the incineration bottle, the temperature collection point should not be less than three; temperature measurement and control point should be linked with the fuel supply system to ensure the timely supply of fuel;
3) burner: 2 (liquefied petroleum gas as gas source). The calorific value of the burner should meet the requirement of the burner. The calorific value of a single burner is 100,000 kcal. The quantity of the burner must be enough to meet the requirement of the burner when the natural gas is used as fuel alone. Equipped with 1 fuel guns (residual gas as gas source).
4) automation: the manipulator automatically delivers bottles.
5) the incinerator should be furnated with refractory materials.
6) Cylinders are sent out of the incinerator through a roller conveyor chain to an on-line cylinder hydraulic testing machine using a combination of natural cooling and strong cooling.
7) the largest size of the incinerator is 14000 * 1200 x 1500mm (long * width * height).
Main technical requirements for flue gas treatment equipment
1) the treatment capacity should be matched with the treatment capacity of the incinerator, which can be greater than the treatment capacity of the incinerator.
2) Dust removal, desulfurization and denitrification should be included to treat the flue gas (including dust, sulfur dioxide, nitrogen oxides and other waste gases) produced in the process of incinerator production so as to meet the national environmental protection requirements